Firmware PowerCable xxx: 4.0.5 (3,4 MB)
2024/03/20
= Firmware for NETIO PowerCable 101x – version 4.0.5 - 1.55 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
- PowerCable 101Y
==== Main system version 4.0.5 ====
- MQTT - fixed REST_JSON variable restart when recieveng a message
- HTTP(s) Push - fixed restart when periodically sending data
- Button soft restart functionality delays is activated after 60 seconds pressed button
- CA root certificate exchange bug in NETIO Cloud MQTT client fixed
==== Low level system verze 1.55 ====
- Added support for PowerPDU 8KS
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
- PowerCable 101Y
==== Main system version 4.0.5 ====
- MQTT - fixed REST_JSON variable restart when recieveng a message
- HTTP(s) Push - fixed restart when periodically sending data
- Button soft restart functionality delays is activated after 60 seconds pressed button
- CA root certificate exchange bug in NETIO Cloud MQTT client fixed
==== Low level system verze 1.55 ====
- Added support for PowerPDU 8KS
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 4.0.1 (3,4 MB)
2023/09/23
= Firmware for NETIO PowerCabke 101x – version 4.0.1-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
==== Main system v 4.0.1 ====
- The API for the main system has been changed, therefore this update is not backwards compatible with pre 4.0.0 versions, once you upgrade to this version and newer, you won't be able to downgrade.
- Syslog - You can now use the syslog (settings -> system) protocol to log the device updates.
- Rules - Sequences - Ability to set seqences of actions with delays in Rule action configuration.
- Rules - Startup rules - Use the device power up conditions in rule conditions.
- PAB - Sunrise & Sunset - "DAYLIGHT" PAB rules based on the sun position in a given geolocation can be used in rule conditions.
- PAB - Fixes in conditioning with rules
- JSON - JSON event that can be used as a condition in rule configuration.
- System - Password brute force attack protection.
- System - Output name and password length increased to 32 characters.
- System - Timezones now display status of DST (Daylight Savings Time). DST is activated automatically.
- MQTT - Support for wildcards in MQTT.
- MQTT - Now includes 'UTC_TIME' variable.
- MQTT - Now allows to subscribe as an event to trigger actions using rules.
- MQTT - New feature called groupEvents, allows to setup a group of different topics to be published by a single event.
- MQTT - Properly supports backlash escape characters in payloads.
- SNMP - Scalar "Zero" when getting value by OID is not required
- Watchdog - Deleting watchdogs no longer causes device restart.
- Watchdog - Limit increased to 32.
- Watchdog - New connectivity rules based on the state of the device networking.
- Watchdog - New behaviour, upon configuration watchdog will be set to 'fail = false' and it will go to a state of rebooting (activates again).
- NETIO Cloud - Output & device name now synchronize with cloud on change.
- Firmware update - fixed issue when firmware update failed sometimes
- Bug fuxes and system optimalization
- Passwords - maximum length extended to 32 characters
==== Low level system v 1.43 ====
- No changes
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
==== Main system v 4.0.1 ====
- The API for the main system has been changed, therefore this update is not backwards compatible with pre 4.0.0 versions, once you upgrade to this version and newer, you won't be able to downgrade.
- Syslog - You can now use the syslog (settings -> system) protocol to log the device updates.
- Rules - Sequences - Ability to set seqences of actions with delays in Rule action configuration.
- Rules - Startup rules - Use the device power up conditions in rule conditions.
- PAB - Sunrise & Sunset - "DAYLIGHT" PAB rules based on the sun position in a given geolocation can be used in rule conditions.
- PAB - Fixes in conditioning with rules
- JSON - JSON event that can be used as a condition in rule configuration.
- System - Password brute force attack protection.
- System - Output name and password length increased to 32 characters.
- System - Timezones now display status of DST (Daylight Savings Time). DST is activated automatically.
- MQTT - Support for wildcards in MQTT.
- MQTT - Now includes 'UTC_TIME' variable.
- MQTT - Now allows to subscribe as an event to trigger actions using rules.
- MQTT - New feature called groupEvents, allows to setup a group of different topics to be published by a single event.
- MQTT - Properly supports backlash escape characters in payloads.
- SNMP - Scalar "Zero" when getting value by OID is not required
- Watchdog - Deleting watchdogs no longer causes device restart.
- Watchdog - Limit increased to 32.
- Watchdog - New connectivity rules based on the state of the device networking.
- Watchdog - New behaviour, upon configuration watchdog will be set to 'fail = false' and it will go to a state of rebooting (activates again).
- NETIO Cloud - Output & device name now synchronize with cloud on change.
- Firmware update - fixed issue when firmware update failed sometimes
- Bug fuxes and system optimalization
- Passwords - maximum length extended to 32 characters
==== Low level system v 1.43 ====
- No changes
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 3.2.6 (3,4 MB)
2022/11/02
= Firmware for NETIO PowerCabke 101x – version 3.2.6-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
==== Main system v 3.2.6 ====
- Scheduler - fix of late afternoon / night interval incorrect saving
- Scheduler - possibility to select again "None" after selecting other before
==== Low level system v 1.43 ====
- No update
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerCable 101F
- PowerCable 101E
- PowerCable 101G
- PowerCable 101S
- PowerCable 101J
==== Main system v 3.2.6 ====
- Scheduler - fix of late afternoon / night interval incorrect saving
- Scheduler - possibility to select again "None" after selecting other before
==== Low level system v 1.43 ====
- No update
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 3.2.5 (3,4 MB)
2022/05/12
= Firmware for NETIO PowerCable 101x – version 3.2.5-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable 101x
==== Main system v 3.2.5 ====
- Activation of static IP mode by button
- Modbus/TCP protocol update for devices with energy metering and digital inputs
- Telnet protocol - commands response format
- MQTT-flex protocol - parameters length update, MS Azure IoT Hub compatibility
- Default PAB, Rules configurations update
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 3.2.0 (3,3 MB)
2021/11/17
= Firmware for NETIO PowerCable_101x – version 3.2.0-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable_101x
==== Main system v 3.2.0 ====
- PAB: (Power Analyzing Block) defines sets of conditions for creating events from the time course of measured variables (current, voltage, S0 pulses etc.). You can then work with events in Rules.
- Watchdog: Watchdog is a tool that allows you to ping a given (IP) address and evaluation of success.
- Rules: Rules allow to trigger follow-up actions based on events from PAB, Watchdog or Digital Inputs (DI). The actions can change output states (turn OFF, turn ON, toggle, etc.) or trigger an alarm in NETIO Cloud.
- Support for NETIO Cloud Premium
- Support for remote FW update from NETIO Cloud
- Support for control by mobile app NETIO Mobile2 over NETIO Cloud
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable_101x
==== Main system v 3.2.0 ====
- PAB: (Power Analyzing Block) defines sets of conditions for creating events from the time course of measured variables (current, voltage, S0 pulses etc.). You can then work with events in Rules.
- Watchdog: Watchdog is a tool that allows you to ping a given (IP) address and evaluation of success.
- Rules: Rules allow to trigger follow-up actions based on events from PAB, Watchdog or Digital Inputs (DI). The actions can change output states (turn OFF, turn ON, toggle, etc.) or trigger an alarm in NETIO Cloud.
- Support for NETIO Cloud Premium
- Support for remote FW update from NETIO Cloud
- Support for control by mobile app NETIO Mobile2 over NETIO Cloud
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 3.1.3 (3,4 MB)
2021/05/11
= Firmware for NETIO PowerCable 101x – version 3.1.3-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable MQTT 101x
- PowerCable Modbus 101x
==== Main system v 3.1.3 ====
- SNMP: support of SNMP v3
- Option to run SNMP in parallel to other M2M API protocol
- MQTT-flex: Longer username (128 chars) a password (256 chard) support for compatibility with MS Azure
- Added Reverse Energy counters - energy delivered back to the grid from connected device
- Added non-resetable Energy counters - Energy NR, Reverse Energy NR, Total Energy NR, Total Reverse Energy NR
- Adjustment of the Phase range: 0° - 360°
- Adjustment of electrical measurement in web administration
- Improved firmware upgrade process
- SNMP bux fixes
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable MQTT 101x
- PowerCable Modbus 101x
==== Main system v 3.1.3 ====
- SNMP: support of SNMP v3
- Option to run SNMP in parallel to other M2M API protocol
- MQTT-flex: Longer username (128 chars) a password (256 chard) support for compatibility with MS Azure
- Added Reverse Energy counters - energy delivered back to the grid from connected device
- Added non-resetable Energy counters - Energy NR, Reverse Energy NR, Total Energy NR, Total Reverse Energy NR
- Adjustment of the Phase range: 0° - 360°
- Adjustment of electrical measurement in web administration
- Improved firmware upgrade process
- SNMP bux fixes
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 3.0.1 (3,3 MB)
2020/11/30
= Firmware for NETIO PowerCable 101x – version 3.0.1-1.31 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable Modbus 101x
- PowerCable MQTT 101x
==== Main system v 3.0.1 ====
- Added the Scheduler feature
- Added the output control over Netio Push M2M API protocol
- Added option to use JSON for the outputs control over MQTT-flex M2M API protocol (target "REST_JSON")
- All models (REST, Modbus a MQTT) now support all M2M protocols - XML, JSON, URL API, Telnet, Modbus/TCP, MQTT-flex, Netio Push and SNMP.
- Bug fixes and the system optimalisation
==== Low level system v 1.31 ====
- The system optimalisation
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 2.5.4 (2,99 MB)
2020/09/02
= Firmware for NETIO PowerCable 101x version 2.5.4 -1.29 release notes =
* Firmware 2.5.4 -1.29 can be used to upgrade from version 2.4.4 and later. If you have an older firmware version, contact technical support at support@netio.eu and provide your version number. You will find your version number at web-interface at the bottom of the screen, eg. 1.2.12 1.17(1.16) 106, or at Settings/Firmware tab.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu-output-restart.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable Modbus 101x
- PowerCable MQTT 101x
==== Main system ver. 2.5.4 ====
- Automatic CA root update (NETIO Cloud)
- Valid backup LetsEncrypt CA root
- Memory optimization
- Added new tags to JSON API, and version bumbed to 2.3
==== Low level system ver 1.29 ====
- Relay driving improvemnt - lower own consumption
- New measurement variables support
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 2.5.1 (2,94 MB)
2020/05/06
= Firmware for NETIO PowerCable xxx version 2.5.1-1.28 release notes =
* Firmware 2.5.1-1.28 can be used to upgrade from version 2.0.2 and later. If you have an older firmware version, contact technical support at support@netio.eu and provide your version number. You will find your version number at web-interface at the bottom of the screen, eg. "1.2.12 1.17(1.16) 106", or at Settings/Firmware tab.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu-output-restart.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable Modbus 101x
- PowerCable MQTT 101x
==== Main system v 2.5.1 ====
- New NETIO Cloud support
- New SNMP support (PowerCable REST only)
- MQTTflex - new default config
- MQTTflex - longer user configuration
- MQTTflex - JSON payload
- MQTTflex - REST JSON pyload in subscribed message
- hostname is generated from device name
- Output start interval - setup moved to output settings
- FW upgrade checks file type
==== Low level system v 1.28 ====
- Improved bootstrap
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 2.3.9 (2,76MB)
2020/03/02
Firmware 2.3.9-1.27 can be used to upgrade from version 2.0.2 and later. If you have an older firmware version, contact technical support at support@netio.eu and provide your version number. You will find your version number at web-interface – at the bottom of the screen, eg. „1.2.12 – 1.17(1.16) – 106“, or at Settings/Firmware tab.
Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerCable REST 101x
- PowerCable Modbus 101x
- PowerCable MQTT 101x
Main system v 2.3.9
- MODBUS coils return correct values
- MODBUS more simultaneous connections
- NFC configuration support - NCI - NFC Command Interface (compatible with NETIO Mobile 2)
- some AP mode issues fixed
- Default device name with the last byte from serial number - fix
- New MQTTflex logs
- Telnet stream handling
- JSON + XML API new serialNumber tag
- JSON + XML API version updated to 2.2
Low level system v 1.27
- Consumption counter minor fixes
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 2.1.0 (1,19MB)
2019/06/25
Firmware 2.0.2 can be used to upgrade version 2.0.2 and newer. If you have an older firmware version, contact technical support at support@netio.eu and provide your version number. You will find your version number at web-interface – at the bottom of the screen, eg. „1.2.12 – 1.17(1.16) – 106“, or at Settings/Firmware tab.
What's new
- configuration export and import
- firmware update stability improvement
- IP mask validator fix
PowerCable Modbus
- Telnet protocol added
PowerCable REST
- new version of PowerCable with API protocols XML, JSON and URL API
PowerCable MQTT
- new version of PowerCable with API protocols MQTT and Netio Push
Known Issues
- AP mode - incorrect warning message when a wrong WiFi pasword entered
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerCable xxx: 2.0.2 (1,08MB)
2019/02/14
ATTENTION – the power output will be turned off during this firmware update!
Firmware 2.0.2 can be used to upgrade version 1.2.12 and newer. If you have an older firmware version, contact technical support at support@netio.eu and provide your version number. You will find your version number at web-interface – at the bottom of the screen, eg. „1.2.12 – 1.17(1.16) – 106“, or at Settings/Firmware tab.
Perform the „Restore Factory Defaults“ after you upgrade to 2.0.2, otherwise some functionalities won’t work correctly. It can be done through web-interface or using button. The device has to be completely set up then including WiFi connection settings in AP mode!
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Power output control system (MCU)
- Updates MCU firmware - the power output will be turned off during this firmware update!
What's new
- M2M API Netio Push –HTTPs support added. Repetitive DNS request when connection fails.
- M2M API XML – incoming file parser fixed. Accept also complete XML status file from NETIO COBRA or NETIO 4x.
- M2M API JSON – incoming file parser fixed. Accept also complete json status file from NETIO COBRA or NETIO 4x. Json syntax fixed. Http header changed - „text/json“ changed to „application/json“.
- Date/Time – default of new devise or after „Restore Factory Defaults“ is “Set time manually”. The time is set to „1970-01-01 12:00:00“ and Timezone shift applied after each start/restart of the device.
- Minor bugs of WiFi connection and others fixed.
Known Issues
- The change to Static IP require device restart.